Meaning
A datasheet is the maker’s published table of a material’s properties, measured on specimens built under the maker’s own named process. EOS, HP, 3D Systems, Formlabs and Stratasys each publish one per grade, and every figure belongs to that grade, machine and parameter set. EOS prints on its PA 2200 sheet that part properties are given for information only. The values are a place to start a requirement, and none of them is an acceptance limit for a delivered part.Test Conditions
Every row carries a test method, a load or speed and a specimen orientation, and those conditions travel with the number. EOS tests heat deflection at 1.80 MPa (261 psi) under ISO 75 and reports 64 °C (147 °F) for PA 2200 in X. HP tests at 1.82 MPa (264 psi) under ASTM D648 and reports 95 °C (203 °F) for High Reusability PA 12 in Z. The loads differ by 0.02 MPa and the results by 31 °C (56 °F). A reader who sets them side by side compares two procedures as well as two powders. On its glass bead sheet, HP pulls its Z tensile specimens at 1 mm/min (0.04 in/min) and its XY specimens at 10 mm/min (0.39 in/min). An EOS footnote adds that its elongation column holds strain at break for brittle behavior and nominal strain at break for ductile behavior.Read More
Statistical Basis
A figure on a datasheet is either a typical value or a statistical lower bound, and the sheet has to say which. The PA 2200 sheet gives typical values. The EOS 316L sheet adds tolerance intervals, lower bounds where 99, 95 or 90 % of the population falls with 95 % confidence. EOS states that those intervals are based on validation data and are not directly transferable to other systems. On the 20 µm (0.0008 in) set, the lowest typical yield is 480 MPa (69.6 ksi). The lowest lower bound printed for that set is 413 MPa (59.9 ksi), and a structural calculation takes that figure.Sample Count
The number of specimens behind a figure says how much weight the figure can carry. EOS reports 363 vertical and 246 horizontal 316L specimens on its 20 µm set. It reports 162 and 72 on the 40 µm set and 120 and 96 on the EOS M 400-4. The Core set, at technology readiness level 3, gives typical figures with no count. A typical figure with no count and no interval is the weakest basis a sheet offers. The buyer asks for the count before writing a limit on it.Build Direction
Most rows of a printed material differ by axis, so the sheet names the axis beside each figure. PA 2200 stretches 18 % in X and Y and 4 % in Z. Its tensile strength moves only from 48 to 42 MPa (6,960 to 6,090 psi). On the 20 µm 316L set, the vertical bar yields 60 MPa (8.7 ksi) below the horizontal bar. The same sheet defines its orientations by ASTM F2971. A buyer comparing two sheets checks that the axis letters mean the same thing on both.Maker Comparison
Two sheets for one polymer can differ in method, specimen and density basis as well as in powder. EOS reports ISO 527 tensile results, and HP reports ASTM D638 results on a type V specimen. EOS gives 0.93 g/cm³ (0.034 lb/in³) for PA 2200 by its own method. HP gives 1.01 g/cm³ (0.036 lb/in³) by ASTM D792, and the two figures do not measure the same thing. The 3D Systems Accura guide states that its figures hold for large-frame printers. Its Accura Xtreme sheet carries a separate glass transition row for ProJet printers.Requirement Wording
A row becomes a requirement when the order names the grade, the parameter set, the method, the orientation and the statistical basis. The cure or heat treatment belongs in the same line. Formlabs gives its Tough 2000 Resin V2 figures after 12 minutes at 70 °C (158 °F) in a Form Cure V2. The Somos EvoLVe 128 sheet warns that values vary with machine processing and post-curing practice. For PA12, the EOS and HP sheets read for these resources publish no creep, fatigue or chemical resistance table. Those values are requested from the maker in writing.