Meaning
A tolerance interval is a statistical lower bound below which only a stated share of the population falls, at a stated confidence. EOS prints them on its 316L sheet beside the typical results. A T99 interval is the bound above which 99 % of the population falls with 95 % confidence. EOS states that its intervals rest on validation data and are not directly transferable to other systems.Levels on One Sheet
The 20 µm set carries T99, the 40 µm set T95 and the EOS M 400-4 set T90. Those are three confidence levels, so one set’s lower bound cannot be laid over another’s without noting the level. On the 20 µm chart, the lower bounds run from 413 to 605 MPa (59.9 to 87.7 ksi) across the strength figures. For elongation they sit at 32 to 33 %.Read More
Design Use
A typical value says what to expect, and a tolerance interval says what to design to. On the 20 µm set, the lowest typical yield is 480 MPa (69.6 ksi). The lowest printed lower bound is 413 MPa (59.9 ksi), which is 67 MPa (9.7 ksi) or 14 % lower. A structural calculation takes the lower bound.Where Sheets Lack It
The polymer sheets in these resources publish no tolerance interval with a confidence level. The PA 2200 sheet gives typical values only. The EOS Core 316L set gives typical figures with no sample count. A buyer who needs a design allowable asks the maker for the interval and its basis.Statistical Basis Line
An order writes whether its acceptance figure is a typical value or a lower bound, and at what confidence level. It asks for the sample count behind the figure, since a figure from 45 samples and one from 363 carry different weight. For a run, the sources give no standard sample size, so the sampling plan is agreed in the order.