Meaning
Measurement is the reading of a printed part’s size or surface with a named instrument, at a named stage, by a named method. The same part gives different numbers before and after post-cure or heat treatment. It also reads differently on the peaks and in the valleys of a rough face. A measurement therefore carries its method and stage with its value, and EOS states that its roughness values depend on the measurement method.Instruments
Each instrument answers its own question. A calibrated height gauge read the Formlabs nylon blocks face to face. An optical 3D scan compares overall form with the model and is the fastest. A tactile coordinate measuring machine (CMM) gives datum and feature dimensions more slowly and more precisely. A stylus gives surface texture, and computed tomography (CT) sees pores and trapped powder inside. Go/no-go gauges and gauge pins check each bore, with no published limit behind them, and a pass or fail is their whole answer. On nylon parts, weighing a few parts against the average is a practical check for trapped powder. MakerVerse lists optical scan, tactile CMM, stylus roughness and CT as the methods a metal part supplier offers.Read More
Stage
A printed dimension is read after the last step that moves it. Resin parts are measured after post-cure, because the cure shrinks them. Nylon parts are measured after unpacking at the agreed temperature. Metal parts are measured after heat treatment, which moves a 316L size by +0.02 % or +0.2 % depending on the set. The EOS process data sheet for 316L-4404 at 40 µm gives a typical change of +0.02 %. A part with a close tolerance is still measured after the treatment, because the figure is typical and not guaranteed.Research Method
A 316L thin-wall study sectioned its specimens and photographed the polished cross-section. It converted each image to black and white and read the wall or gap at the half gray value. Each condition had 2 specimens, and roughness came from 6 outlines of the side wall. The method suits a study of mechanisms and differs from how a supplier inspects a delivered part. The Formlabs nylon study worked differently. It placed 6-dimension witness blocks at 4 corners and 3 heights of a packed chamber. Their features measured 25, 50, 100 and 138 mm (0.98, 1.97, 3.94 and 5.43 in). A calibrated height gauge read them over 5 builds. Deviation from the average stayed within 0.25 mm (0.010 in) in XY at every size, about ±0.3 %.Roughness Inside a Size
A rough face blurs a dimension. A roughness of Ra 13 µm (512 µin) is a third of a 0.04 mm (0.0016 in) tolerance band. At higher power, the top surface of a thin wall can carry humps of about 200 µm (0.008 in). Those humps belong to the geometry, and no gauge removes them. Roughness is reported as Ra, Rz or Sa, and the measure is named with the value. EOS gives Ra and Rz for 316L as built and charts Sa against build angle for upward and downward faces. Those chart values are not printed as numbers, so a buyer asks for the figure on the actual surface.Reporting
A measurement report names the method, the stage, the build position and the number of parts. On laser-sintered nylon, it also gives any scale factor applied to the file. In the Formlabs study, 40 readings per axis came from blocks at 4 corners and 3 heights of a packed chamber. That study measured solid blocks only. A buyer who needs a figure for holes, thin walls or flatness asks for it on the same terms. ISO/ASTM 52902 describes test artefacts for judging the geometric capability of a system. It specifies what to measure and the quality of the measurement, and leaves the method and the build of the pieces open. A supplier that has run such artefacts holds measured data for its own feature types.