Meaning
Accuracy is how close a measured dimension of a printed part comes to its value in the computer-aided design (CAD) model. The Formlabs guide separates it from “precision”, how repeatable results are, and from tolerance, the range a buyer accepts. A machine can be precise and still inaccurate, with every part the same and all of them 0.1 mm (0.004 in) over. Only inspection of real parts shows how a statement splits between them.Published Figures
Makers state accuracy as a band that grows with feature size. For stereolithography (SLA), Formlabs gives ±0.15 % on features of 1 to 30 mm (0.04 to 1.18 in). It gives ±0.3 % on features of 81 to 150 mm (3.19 to 5.91 in). Its floor is ±0.02 mm (±0.0008 in). The 3D Systems SLA 750 states ±0.051 mm (±0.002 in) below 34 mm (1.34 in) and 0.15 % cumulatively above. For selective laser sintering (SLS) of nylon, Formlabs gives ±0.5 % or 0.3 mm (0.012 in) in XY, whichever is larger. EOS gives about ±20 to 50 µm (±0.0008 to 0.002 in) for small 316L parts and about 0.2 % for large ones.Read More
Basis of the Statement
The EOS figure for 316L rests on users’ experience of typical geometries. It is about 40 µm (0.0016 in) when parameters are tuned for a class of parts. It is about 60 µm (0.0024 in) on a new geometry built for the first time. The Formlabs nylon figures come from 100 mm (3.94 in) witness blocks measured over 5 builds on one machine and one powder.Offset and Scatter
Inaccuracy has two parts that behave differently. In the Formlabs nylon study, the 100 mm XY block averaged 100.22 mm (3.946 in), an offset of 0.22 % that repeated in every build. Scaling the file removes that offset and leaves a scatter of about ±0.17 mm (±0.007 in). At the top of a build, Z blocks read 0.58 % tall with little scatter. A correction taken there misfits the lower zones.Process Effects
Post-cure shrinks resin parts, and print preparation software compensates for it in some cases. A nylon chamber unpacked at 100 °C (212 °F) gave about twice the warp of one unpacked at room temperature. On a 316L thin wall, laser power and contour offset set the error. With a contour scan, the wall error ran from 91.9 to 199.7 µm (0.0036 to 0.0079 in). Without one it ran from 165.6 to 347.8 µm (0.0065 to 0.0137 in).Across Processes
At 100 mm (3.94 in), the statements give about ±0.3 mm (±0.012 in) for Formlabs SLA. They give ±0.15 mm (±0.006 in) for the SLA 750. They give ±0.5 mm (±0.020 in) for SLS, for Multi Jet Fusion (MJF) and for fused deposition modeling (FDM). For 316L they give about ±0.2 mm (±0.008 in). Formlabs places resin and powder printing between standard machining and fine machining. A feature closer than 0.025 mm (0.001 in) may need a machining step after printing.