Meaning
Melting point is the temperature at which a polymer powder melts, measured on datasheets under ISO 11357 or ASTM D3418. For a powder bed it sets how close to melting the cake runs and how long the parts stay soft after the build. It sits far above the temperature a part can carry in service. HP lists it among its powder properties, beside particle size and bulk density.Values
EOS PA 2200 melts at 176 °C (349 °F) under ISO 11357. HP High Reusability PA 12 melts at 187 °C (369 °F) by differential scanning calorimetry under ASTM D3418. Its glass bead grade melts at 186 °C (367 °F). The PA 2200 Vicat softening point B50 is also 176 °C.Read More
Service Limit
The temperature a part can carry under load is far below its melting point. PA 2200 deflects at 64 °C (147 °F) under 1.8 MPa (261 psi), more than 100 °C below its melting point. HR PA 12 deflects at 95 °C (203 °F) under 1.82 MPa. A part is read against the loaded heat deflection row, not the melting row.Cooling
Nylon 12 sinters near its melting point and stays soft for a long time after the laser has gone. A cake that has fallen to 100 °C (212 °F) is far below melting, but the parts inside are still shrinking. Formlabs therefore unpacks at 50 °C (122 °F) and no higher than 70 °C (158 °F).Feedstock Testing
ISO/ASTM 52927 makes testing the feedstock one of its 3 layers of testing. HP’s powder rows show what that layer holds for nylon: melting point, particle size and bulk density. An order can ask for those rows per powder lot.